Application/type |
Room sensor |
Purpose |
Measure values |
Measured values |
temperature, relative humidity, absolute humidity, enthalpy, dew point, CO2, VOC, CO2/VOC mix |
Interface |
Active, 0..5 V, 0..10 V, 4..20 mA |
Configuration |
NOVOSapp, uConfig, each output can be set to get a variable mix of CO2 and VOC by configuration via app or uConfig, (depending on type) |
Output voltage |
0..10 V or 0..5 V, 2x 0..10 V or 0..5 V, 3x 0..10 V or 0..5 V, 4x 0..10 V or 0..5 V, live-zero configuration via app or uConfig, min. load 10 kΩ |
Output current |
4..20 mA, 2x 4..20 mA, max. load 500 Ω |
Operating range temperature (°C) |
0..+50 |
Operating ranges temperature (°C) |
0..+50 |
Output signal temperature |
0..+50 °C (default setting), selectable from 4 temperature ranges -50..+50 | 0..+50 | -20..+80 | -15..+35 °C, optionally configurable |
Operating range humidity |
max. 85% rH non-condensing |
Accuracy temperature |
±0,5 K (typ. at 21 °C) |
Measuring range humidity |
0..100% rH non-condensing, 0..85 KJ/kg enthalpy, 0..50 | 0..80 g/m³ absolute humidity, 0..+50 | -20..+80 °C dew point, optionally configurable |
Accuracy humidity |
±2% between 10..90% rH (typ. at 21 °C) |
Measuring range CO2 |
0..2000 ppm, 0..5000 ppm, optionally configurable |
Accuracy CO2 |
±50 ppm +3% of measured value (typ. at 21 °C, 50% rH, 1015 hPa), self-calibration Dual Channel |
Measuring VOC (mixed gas) |
heated metal oxide semiconductor |
Power supply |
15..35 V = SELV, 19..29 V ~ SELV |
Power consumption |
typ. 0,4 W (24 V =), 0,8 VA (24 V ~) |
Display |
ePaper Display 44x24 mm, with traffic light function, threshold values configurable, optionally configurable via app or uConfig |
Enclosure |
PC V0 |
Colour |
pure white, black |
Protection (IP) |
IP20, according to EN 60529 |
Connection |
tool-free mountable spring clamp, max. 1,5 mm², cable entry via rear opening, predetermined breaking point (bottom) or drilling mark (top) |
Mounting |
flush-mounted on standard EU box (Ø=60 mm), flush-mounted in standard EU box (Ø=60 mm, depth min. 45 mm), surface-mounted flat on base using adhesive foil or screws, base part can be mounted and wired separately |
Packaging length (mm) |
115 |
Packaging width (mm) |
105 |
Packaging height (mm) |
30 |
Packaging |
case packaging |
Device length (mm) |
110 |
Device width (mm) |
100 |
Device height (mm) |
23 |
Notes |
+ surcharge for design cover (mandatory), please select colour, mixed gas sensors detect gases and vapours which can be oxidised (burnt): Body odours, tobacco smoke, exhalations emitted by materials (furniture, carpets, paint, glue ...) |
Option enclosure |
ePaper Display 44x24 mm |
Gefahrgut |
No |